SPECIFICATIONS
• These efficient air handlers with fixed speed PSC blower motors are designed for use with a boiler loop, and packed with most wanted features
• They are AHRI matched to RSG-HRG “M & P” Series split system condensers (see charts inside)
Application
• Multi-Position Design – Shipped upflow or horizontal right from the factory, can be field converted to downflow or horizontal left applications
• Line Voltage Terminal Block – Allows fast, simple thermostat connection
• Slide-Out Blower Assembly – Mounted on rails to make maintenance and service fast
• Freeze Protection for Both Heating & Cooling – Protects the entire system year-round
• R-410A Factory Installed TXV – Provides reliable refrigerant metering
• 3/4” Water Connections – Assures correct water supply lines
Multi-Blower Speed
• Direct drive blower with three speeds easily selected via motor terminals
• Shipped from the factory with disposable filter in the filter rack
Electric Supply
• 120V, 60 Hz system
• Low voltage terminal block
• Connections can be made from cabinet top or left side
Hydronic Heat
• Comes with hydronic heat coil installed
• Controls are accessible from the front
• Freeze stat wired into circulating pump control circuit
Cabinet Features
• Durable galvanized steel cabinet has painted front panels
• 1/2” faced insulation throughout protects against sweating,
enhances efficiency
Evaporator Coil
• Copper tube/enhanced aluminum fins
• Non-corrosive drain pans
• Primary and secondary drain connections with alternate right side
primary